What was found
CRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS500C AFT SIDE LBL25 WL155. ; / [01] FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM; [02] VERIFIED OUT OF LIMITS DUE TO NO SRM LIMITS; [03] LOCATED AND DRILLED NEW ANGLE P/N: 143A7502U155 LOT: 1458822-5 . IAW SRM 51-40-05 AND DWG:143A7505 ID: 0009 REV:A REQUEST OK TO INSTALL; [04] VERIFIED LOCATED AND DRILLED NEW ANGLE P/N: 143A7502U155 LOT: 1458822-5 . IAW SRM 51-40-05 AND DWG:143A7505 ID: 0009 REV:A.<BR>VERIFIED OK TO INSTALL;.; [05] INSTALLED NEW ANGLE P/N: 143A7502U155 LOT: 1458822-5 . IAW SRM 51-40-02 AND DWG:143A7505 ID: 0009 REV:A; [06] VERIFIED INSTALLED NEW ANGLE P/N: 143A7502U155 LOT: 1458822-5 . IAW SRM 51-40-02 AND DWG:143A7505 ID: 0009 REV:A.; [07] VERIFIED ALL STEPS COMPLETE.