What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS400 TO BS420 LBL23 WL156. ; / CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIG 103 DETAIL REMOVED FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS 400 TO BS 420 LBL 23 WL 156 PER SRM 51-40-02-0G-0 FABRICATED NEW FLOOR TO SIDEWALL SUPPORT BS 396 TO 500D L/H; AND SPLICE REPAIR BS 480 TO 500 L/H FROM EXTRUSION CLAD BAC1496-444#7075T62 LOT# 1466509-1 PER SRM 53-00-53-2R-5; SRM51-40-05-0G-0; AND DWG 143A7501LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT AND SPLICE REPAIR PER PER SRM 53-00-53-2R-5; SRM51-40-05-0G-0; AND DWG 143A7501] INSTALLED SPLICE REPAIR PER SRM 53-00-53--2R-5 AND DWG 143A7501] INSTALLED FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BS 396 TO500D LBL 23 WL 156 PER SRM 51-40-02-0G-0; AND DWG 143A7500