What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS499 LBL24 WL156. ; / [01] CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIGURE 103 DETAIL D. NEW FLOOR TO SIDEWALL SUPPORT FROM BS 396 TO BS 500D LBL 24 WL 156 WILL BE INSTALLED ON FAULT TTG8Q00687YP.; [02] VERIFIED OUT OF LIMITS PER SRM 53-00-53-1A-2; REPLACEMENT ON TTG8Q00687YP; JOB COMPLETE.