What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT FROM STA 727 TO STA 767; RBL 22; WL 154. ; / [01] UPDATED MEASUREMENTS; [02] CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLE PER SRM 53-00-53-1A-2 FIG 103 DETAIL D; [03] UPDATED STATEMENT OF CORRECTIVE ACTION BLOCK 1. CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIG 103 DETAIL D; [04] UPDATED STATEMENT OF CORRECTIVE ACTION BLOCKS 2 AND 3. CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIG 103 DETAIL D; [05] VERIFIED CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER SRM 53-00-53-1A-2 FIG 103 DETAIL D; [06] REMOVED ACB FLOOR TO SIDEWALL SUPPORT AT BS727 - BS767; RBL22; WL154 PER SRM 51-40-02-0G-0; [07] LOCATED AND DRILLED ACB FLOOR TO SIDEWALL SUPPORT AT BS727 - BS767; RBL22; WL154 PER SRM 51-40-05-0G-0 AND DWG 146A7500; [08] VERIFIED CORRECTIVE ACTION 7.; [09] OK TO INSTALL RH FLOOR-TO-SIDEWALL SUPPORT; [10] INSTALLED FLOOR TO SIDEWALL SUPPORT BS 727 TO 767; RBL22; WL154 IAW SRM 51-40-02 AND DWG 146A0061; DWG 146A7502 AND DWG 146A7502; [11] VERIFIED INSTALLATION OF RH FLOOR-TO-SIDEWALL SUPPORT; BS 727-767; RBL 22; WL 154; PER SRM 51-40-02 AND DWG 146A0061 AND DWG 146A7502; [12] VERIFIED ALL WORK COMPLETE THIS TASK