What was found
CORROSION ON SUPPORT ANGLE BS 1016+23' RBL 6 - RBL 12 W/L 306.5<REMOVED 3EA FASTENERS AT SUPPORT ANGLE BS.1016+23 RBL.9 TO RBL.12 IAW SRM 51-40-02 REMOVED CORROSION AT SUPPORT ANGLE BS.1016+23 RBL.9 TO RBL.12 REWORKED DIMENSION L:3' X W:0.750' IAW SRM 51-10-02. HFEC INSPECTED ANGLE BLENDOUT AREA IAW B737 NDTM P6 51-00-00 PROC 23. NO CRACKS NOTED. HFEC INSPECTED OPEN HOLES IAW B737 NDTM P6 51-00-00 PROC 16. LOCATED AND DRILLED ANGLE BS 1016+23 LBL 12 - RBL 12 IAW SRM 51-40-05 DWG# 148A3110. APPLIED CHEMICAL CONVERSION COATING ON ANGLE PER SRM 51-20-01