What was found
CRACK SUPPORT ANGLE LOCATED ON BS1016 AT VERTICAL STABILIZER ; 2021-392962 / [01] REMOVED SUPPORT ANGLE LOCATED ON BS1016 AT VERTICAL STABILIZER IAW SRM B737-700 51-40-02 AND PERFORMED VISUAL INSPECTION AND NO FOUND MORE DAMAGE; [02] STEP 1 COMPLETE; [03] DRILLED NEW ANGLE IAW SRM B737-700 51-40-05 LOCATED ON BS1016 AT VERTICAL STABILIZER; [04] APPLIED PROTECTIVE TREATMENT ON NEW ANGLE HOLES LOCATED ON BS1016 AT VERTICAL STABILIZER IAW SRM B737-700 51-20-01; [05] OBTAINED OK TO INSTALL NEW ANGLE LOCATED ON BS1016 AT VERTICAL STABILIZER; [06] STEP 3 COMPLETE <BR>RII; [07] STEP 4 COMPLETE; [08] OK GRANTED IN STEP 5<BR>RII ACCOMPLISHED; [09] LATE ENTRY: NO FOUND ALLOWABLE DAMAGE FOR CRACK ON SUPPORT ANGLE; AND MUST BE REPLACED. MEASURES OF CRACK ON ANGLE IS : 0.290 TOOL USED IS CALIPER P/N: 500-464 ; S/N: 15331936 AND DUE DATE: 05-OCT-21.; [10] INSTALLED SUPPORT ANGLE AND FASTENERS ; LOCATED ON BS1016 AT VERTICAL STABILIZER IAW B737-700 SRM 51-40-02 AND DWG 176A3001 SHEET 8 REV -.; [11] STEP 9 COMPLETE; [12] STEP 10 COMPLETE<BR>RII ACCOMPLISHED; [13] REPLACED SUPPORT ANGLE LOCATED ON BS1016 AT VERTICAL STABILIZER IAW B737-700 SRM 51-10-02 ; 51-40-02 AND DWG 176A3001 SHEET 8 REV -.; [14] TASK CARD COMPLETED