What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEE N BS 277 AND BS 294.5 BL 0 FWD GALLEY AND LAV ; 2021-393045 / [01] TOOK MEASURE CRACK LENGTH IS 0.160 DUE TO NOT FOUND ALLOWABLE DAMAGED ON SRM B737-700 ; WEB INTERCOSTAL MUST BE REPLACED ; TOOL USED : CALIPER P/N : 500-464 ; S/N : B16066721 ; DUDE DATE : 26/FEB/ 22; [02] REMOVED WEB-INTERCOSTAL FLOOR STRUCTURE LOC.BETWEEN BS 277 AND BS 294.5 BL 0 IAW SRM B737-700 51-40-02 AND PERFORMED VISUAL INSPECTION AND NOT FOUND ADDITIONAL DAMAGED; [03] STEP 1 & 2 COMPLETED.; [04] OBTAINED OK TO INSTALL WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 277 AND BS 294.5 BL 0 FWD GALLEY AND LAV; [05] COMPLETED STEP 4<BR>OK TO INSTALL WEB<BR>RII; [06] INSTALLED WEB- INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN BS 277 AND BS 294.5 BL 0 FWD GALLEY AND LAV<BR>IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 20 REV -.; [07] REPLACED WEB- INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN BS 277 AND BS 294.5 BL 0 FWD GALLEY AND LAV <BR>IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 20 REV -.; [08] RII; STEPS 6 & 7 COMPLETED. <BR>CERTIFIED RII WORK PERFORMED.