What was found
SUPPLEMENTAL INFORMATION: R/H WING FUELING STATION AT PANEL 621GB LIGHT CORROSION ON BRACKET FOR #1 TANK QUANTITY GAUGE. MRKD / R&R'D REFUELING PANEL PER MM 28-41-61 STILL REQUIRES OPS CHECK. OPS CHECK GOOD IAW M/M 28-41-61.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SUPPLEMENTAL INFORMATION: R/H WING FUELING STATION AT PANEL 621GB LIGHT CORROSION ON BRACKET FOR #1 TANK QUANTITY GAUGE. MRKD / R&R'D REFUELING PANEL PER MM 28-41-61 STILL REQUIRES OPS CHECK. OPS CHECK GOOD IAW M/M 28-41-61.