What was found
CRACK INDICATION FOUND ON HORIZONTAL PRESSURE DECK LOCATED BS 663 PLUS 3 INCHES AND BETWEEN LBL 30 AND LBL 40; CRACK LENGTH 0.400 INCHES. INSTALLED REPAIR PARTS DOUBLER [1] 1 EA; WEB [3] 1 EA; STIFFENERS [2] 7 E/A; FILLER[4] 1EA; FILLERS 6EA; FILLER 1 EA; FILLER 1EA; FILLER 1EA; BRACKET (FITTING)1EA BRACKET (2EA) LOC AT BSTA 663.75. AND BTW LBL 30 TO LBL 40. BRACKET (1EA) LOC AT BSTA 675 AND BTW LBL 30 TO LBL 40, STIFFENER (1EA) LOC. BTW BSTA 663.75 TO BSTA 675. AND BTW LBL 50 TO LBL 60. BRACKET (1EA) LOC BTW BSTA 663.75 TO BSTA 675 AND LBL50, BRACKET (1EA), SHIM (1EA) LOCATED BTW BSTA 675 TO BSTA 684 AND LBL 40, SUPPORT