What was found
CRACK ANGLE LOCATED BETWEEN BS 907 TO BS 927 AND STR 25R TO STR 27R FWD POSITION AFT CARGO COMPARTMENT ; 2021-369350 / [01] REMOVED ANGLE (STIFFENER) AND FASTENERS LOC. BTW BS 907 T0 BS 927 AND STR 25R TO STR 27R FWD POSITION AFT CARGO COMPARTMENT MEASURE OF CRACK IS L: 4.10 AND NOT FOUND ALLOWABLE DAMAGE FOR THIS PART IN THE SRM.<BR>MUST BE REPLACED. AND PERFORMED VISUAL INSPECTION ON AREA AND NOT FOUND MORE DAMAGE. IAW B737-700 SRM 51-40-02; [02] STEP 1 COMPLETED; [03] MADE ANGLE(STIFFENER) AND DRILLED LOCATED BTW BS 907 TO BS 927 AND STR 25R TO STR 27R AFT CARGO COMPARTMENT IAW DRAWING 147A7221 REV:D AND SRM B737-700 51-40-05; [04] COMPLETED STEP 3 RII; [05] APPLIED PROTECTIVE TREATMENT ON ANGLE(STIFFENER) LOCATED BS 907 TO BS 927 AND STR 25R TO STR 27R FWD POSITION AFT CARGO COMPARTMENT IAW SRM B737-700 51-20-01; [06] STEP 5 COMPLETE; [07] OK TO INSTALL NEW ANGLE (STIFFENER) LOC. BS 907 TO BS 927 AND STR 25R TO STR 27R FWD POSITION AFT CARGO COMPARTMENT.; [08] CERTIFIED STEP 7; [09] OK TO INSTALL GRANTED RII; [10] INSTALLED NEW ANGLE (STIFFENER) LOC. BS 907 TO BS 927 AND STR 25R TO STR 27R FWD POSITION AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02 AND DWG 147A7221 SHEET 17 REV. D; [11] REPLACED ANGLE (STIFFENER) AND FASTENERS LOC. BS 907 TO BS 927 AND STR 25R TO STR 27R FWD POSITION AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02 AND 51-10-02. DWG 147A7221 SHEET 17 REV. D.; [12] CERTIFIED STEP 10 AND STEP 11.; [13] CERTIFIED STEP 10 AND STEP 11.; [14] JOB COMPLETED RII