What was found
DELAMINATION FOUND ON REPAIR AREA UPPER AND LOWER ON ACCESS PANEL 322B LEADING EDGE. REMOVED REPAIR PLIES AND PREPARED REPAIR AREA IAW SRM 51-70-04-2R-10, REPAIR 10, PARAGRAPH 4. B; C. INSTALLED A NEW REPAIR IAW SRM 51-70-04-2R-10, REPAIR 10, PARAGRAPH 4. C - E, AND SRM 51-70-04-0 REPAIR GENERAL PARAGRAPH 4. E; L; M.