What was found
CRACKED ANGLE LOCATED BS 693 AND RBL 24. REMOVED ANGLE IAW SRM 51-40-02. FORMED ANGLE IAW SRM 51-30-01, AND DWG 273A9112. HEAT TREATED TO 7075T73 IAW BAC5602, TABLE IV, AND TABLE XI. DRILLED THE NEW ANGLE IAW SRM 51-40-05 AND APPLIED PROTECTIVE TREATMENT IAW SRM 51-20-01. INSTALLED THE NEW ANGLE IAW SRM 51-40-02 AND DWG 273A9110, REV-.