What was found
CRACKED ANGLE, BS 693, LBL 24. REMOVED ANGLE IAW SRM 51-40-02. FORMED A NEW ANGLE IAW SRM 51-30-01 & DWG 273A9112, REPAIR ANGLE HEAT TREATED TO 7075-T73 IAW BAC5602 TABLE IV AND TABLE XI. DRILLED THE NEW ANGLE IAW SRM 51-40-05 AND APPLIED PROTECTIVE TREATMENT IAW SRM 51-20-01. INSTALLED THE NEW ANGLE IAW SRM 51-10-02 ITEM 9, SRM 51-40-02, AND DWG 273A9112, REV- AND DWG 273A9110, REV.