What was found
DAMAGED FLOOR PANEL 232RF IN CABIN, EVALUATED AND FOUND WITHIN LIMITS IAW SRM 53-00-50-2R-1, REPAIR 1, PARAGRAPH 1.A. REMOVED DAMAGED SKIN AND INSERTS IAW SRM 53-00-50-2R-1, REPAIR 1, PARAGRAPH 3. B - D. DRIED AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1, REPAIR 1, PARAGRAPH 3. E & F. INSTALLED REPAIR IAW SRM 53-00-50-2R-1 REPAIR 1 PARAGRAPH 3.K. & L.