What was found
SUPPLEMENTAL INFORMATION: FWD CARGO BAY; FLOOR TO SIDE WALL SUPPORT CORRODED; BS500+4; 10; 14; 18;19;22; 30; 34; 42; 46; LBL24; WL156 / REMOVED CORROSION ON FLOOR TO SIDEWALL SUPP0RT AT DISCREPANCY AREA .FOUND TO BE OUT OF LIMITS AT BS 500 +4 L=1.6' W=0.6' D=0.14' ORIGINAL THICKNEES 0.040' REMAINING MAT=0.026' PER IAW 53-00-53-1A-2 FIG 103 CORECTION :USED TOOL ID ATS1672 DATE DUE 03/2022 VERIFIED CORRECTIVE ACTION 1 AND 2. CORRECTION:INFORMATION MEASUREMENTS VERIFIED CORRECTIVE ACTION 4 FABRICATED FLOOR TO SIDEWALL SUPPOR ZEE FROM BAC1496-444 7075T62 LOT#1467644-1 FROM BS400 TO 500D LBL24 IAW SRM 53-00-53-2R-6 REPAIR 6. OK TO TREAT AND PRIME REPAIR PARTS VERIFIED FABRICATED FLOOR TO SIDEWALL SUPPOR ZEE FROM BAC1496-444 7075T62 LOT#1467644-1 FROM BS400 TO 500D LBL24 IAW SRM 53-00-53-2R-6 REPAIR 6. FABRICATED (1EA) SPLICE SIDEPLATE FROM BAC1496-444 7075T62 LOT#1467644-1 LOCATED AT BS480+10LBL24WL.156 IAW SRM 53-00-53-2R-6 REPAIR 6 TABLE 201 [2]. VERIFIED CORRECTIVE ACTION STEP 8. APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON ALL REPAIR PARTS IAW SRM 53-00-53-2R-6PARAG.4.I.J. & SRM 51-20-01-0G-0 AND SOPM 20-41-02. OK TO INSTALL. VERIFIED CORRECTIVE ACTION STEP 10. VERIFIED OK TO INSTALL. INSTALLED AT FWD. CARGO BAY FLOOR TO SIDEWALL SUPPORT LOCATED BTW BS 400 - BS. 500D LBL 24 WL 156. IAW SRM 51-40-02 DWG# 143A7500 AND DWG#143A7505. VERIFIED CORRECTIVE ACTIONS 12