What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS899 RBL22 WL170. ; / [11] INSTALLED SPLICE ON FLOOR TO SIDEWALL SUPPORT OF AFT CARGO BAY AT BS887 RBL22 WL170. I.A.W. DWG# 146A7502; SRM 51-40-02.; [12] VERIFIED CORRECTIVE ACTION 11.; [13] OK TO INTALL; [14] OK TO INSTALL GIVEN.; [15] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT AFT BS 887-BS947 RBL22 WL170 . IAW 773-700 SRM 51-40-02-0G-0; DWG 147A7500 . ALL REQUIRED MAINTENANCE ACTIONS ARE COMPLETE=REQUEST FINAL BUYOFF; [16] ALL REQUIRED MAINTENANCE ACTIONS ARE COMPLETE=REQUEST FINAL BUYOFF; [17] VERIFIED CORRECTIVE ACTION ITEM 15.; [18] VERIFIED TASK IS COMPLETE.