What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT IN THE AFT CARGO BAY, BS 807 - 727C, LBL 21, WL 156. FABRICATED, LOCATED, AND DRILLED A NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0, AND DWG 146A7500, FABRICATED LOCATE AND DRILLED A DOUBLER IAW SRM 53-00-53-2R-6, REPAIR 6, APPLIED CHEMICAL CONVERSION COATING. APPLIED PRIMER IAW SOPM 20-44-04. INSTALLED THE NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 146A7500.