As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND 14' DIAGONAL CRACK IN VAPOR BARRIER LEFT W/W; FWD SPAR. ; FOUND 14' DIAGONAL CRACK IN VAPOR BARRIER LEFT WW; FWD SPAR. LBL 33.5; 4.5 DOWN FROM UPPER WEB TO LBL38..5 AND 5.25' UP FROM BOTTOM. / [01] PERFORMED SRM 57-10-10-1A-2 PARAGRAPH 2(C)(4)(A) STOP DRILL AND SEAL - DVI EVERY 1200 CYC - INTERIM REPAIR