What was found
FWD CARGO; DOOR SURROUND STRUCTURE; AFT SHIELD CORRODED AT FASTENER HOLES STA 500+6' TO STA 500+10'; RBL 24; WL 156 / REMOVED CORROSION FROM AFT SHIELD FWD PIT IOAW SRM 51-10-02-0G-0 ORIGINAL THICKNESS .032 .028 MAT'L REMOVED .004 MAT'L REMAINS OUT OF LIMITS SRM 53-30-15-1A-1 LOCATED + DRILLED NEW SHIELD IAW DWG 143A8126 REV - INSTALLED NEW SHIELD IAW SRM 51-40-02-0G-0 P/N 143A8126-38 ATAG WN8776