What was found
SUPPORT INTERCOSTAL IS CORRODED ON UPPER SURFACE AT BS 259 - 270, WL 207.54, LBL 3 - RBL 3. REMOVED DAMAGE ON INTERCOSTAL IAW SRM 51-10-02-0G-0. ORIGINAL MATERIAL THICKNESS .040' IAW SRM 53-10-51-0I-2, REMAINING MAT. THICKNESS .030' FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1 ALLOWABLE DAMAGE 1; STEP 4.B. 2, FIGURE 105. REMOVED INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW SUPPORT INTERCOSTAL IAW SRM 51-40-05, AND DWG 141A5210. INSTALLED SUPPORT INTERCOSTAL IAW SRM 51-40-02, AND IAW DWG 141A5210.