What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS767 - BS727B RBL21 WL156. ; / [01] REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT AT BS727B - BS767 RBL 21 WL 156 ; ORIGINAL THICKNESS IS 0.040' ; MAXIMUM MATERIAL REMOVED IS 1'X1.5'X0.011' ; REMAINING THICKNESS IS 0.029' ; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; [02] VERIFIED REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT AT BS727B - BS767 RBL 21 WL 156 ; ORIGINAL THICKNESS IS 0.040' ; MAXIMUM MATERIAL REMOVED IS 1'X1.5'X0.011' ; REMAINING THICKNESS IS 0.029' ; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2.