What was found
FWD CARGO LH TRANSITION ANGLE FROM STA 500-500D; WL 156.5 AT LBL 24 HAS AREAS OF CORROSION AT FASTENER HOLES. (MARKED) ; / [01] WHILE REMOVING CORROSION ;FOUND AREA OUT OF LIMITS PER SRM 53-00-53-1A-2.[0.0 08] REMOVED; [02] LOCATED AND DRILLED HOLES FROM STA 490 TO STA 500D LBL 24(EXISTING SPLICE). PER SRM 51-40-05; [03] APPLIED ALODINE TO PARTS PER SRM 51-20-01; [04] VERIFIED CORRECTIVE ACTIONS 2 AND 3; [05] MATCH DRILLED REPLACEMENT TRANSITION ANGLE PER SRM 51-40-02; INSTALLATION ON FAULT 5330-E-16461-NG (CPCP/AD MOC - FWD CARGO COMPARTMENT FLOOR STRUCTURE CORROSION PROTECTION) [TTG8Q004E4SE]; [06] C/W INSPECTION.