What was found
CRACKED CORRUGATED PLATE TRAILING EDGE BTW WS 253.00 TO WS 278.50 LT WING. REMOVED CORRUGATED PLATE IAW SRM 51-40-02, AND PERFORMED VISUAL INSPECTION ON ADJACENT AREA AND NO FOUND ADDITIONAL DAMAGE. NO FOUND ALLOWABLE DAMAGE IN SRM. DRILLED NEW CORRUGATED PLATE IAW SRM 51-40-05 AND APPLIED PROTECTIVE TREATMENT ON NEW HOLES IAW SRM 51-20-01. INSTALLED CORRUGATED PLATE IAW SRM 51-40-02 AND DWG 115A2714 REV - REPLACED CORRUGATED PLATE IAW SRM 51-40-02, SRM 51-10-02 PARAGRAPH 9, AND DWG 115A2714 REV -.