What was found
CRACK ANGLE LOCATED BS500C BTW STR25 TO STR26R FWD CARGO COMPARTMENT. REMOVED ANGLE IAW SRM 51-40-02 DUE TO NO FOUND ALLOWABLE DAMAGE ON SRM LENGTH OF CRACK IS 0.202 INCH AND PERFORMED VISUAL INSPECTION ON AREA AND NO FOUND DAMAGE. DRILLED NEW ANGLE IAW SRM 51-40-05. INSTALLED NEW ANGLE AND FASTENER IAW SRM 51-40-02 AND DWG 143A7505 SHEET 6 REV D. REPLACED ANGLE IAW SRM 51-10-02 TEM 9; SRM 51-40-02 AND DWG 143A7505 SHEET 6 REV D.