What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328; RBL30 AT FWD GALLEY AREA. REMOVED WEB AND FASTENERS LOCATED BETWEEN BS 312 TO BS 328, RBL 30 AT FWD GALLEY AREA IAW SRM 51-40-02 REMOVAL WEB AND DID NOT FIND ADDITIONAL DAMAGE. MEASURES OF LENGTH CRACK IS: 2.028 INCH. DRILLED NEW WEB - INTERCOSTAL IAW SRM 51-40-05. INSTALLED NEW WEB - INTERCOSTAL IAW SRM 51-40-02, AND DWG 141A5400, REV -.