What was found
R/H TRANSITION ANGLE HAS CORROSION AT NUT PLATE HOLES RBL 24 STA 500A+15. BLENDED AREA OF CORROSION, REMOVED 0.009; ALLOWED 0.004; BLEND OUT OF LIMITS IAW SRM 53-00-53-1A-2. FABRICATED FWD CARGO RT TRANSITION ANGLE IAW DRAWING 143A7501-198, TASK CARD TTG8Q006PK6F AND TASK CARD TTG8Q004G0Y8. FABRICATED THE TRANSITION ANGLE IAW DRAWING 143A7501-198, TASK CARD TTG8Q006PK6F AND TASK CARD TTG8Q004G0Y8. APPLIED BMS 10-11 TYPE II ENAMEL ON TRANSITION ANGLE IAW SOPM 20-41-02 AND TASK CARD TTG8Q006PK6F.