What was found
AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT IS CORRODED AT WL 153, BS 727C+11, RBL 20, BS 727C+18.5, RBL 20, BS 727D+3, RBL 22, BS 727D+4.5, RBL 20, BS 727D+5.5, RBL 20, BS 727D+7.5, RBL 20, BS 727D+10, RBL 20, BS 727D+10, RBL 22, BS 727D+13, RBL 20, & BS 727D+14, RBL 22. FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. LOCATED & DRILLED NEW SPLICE SIDEPLATE IAW SRM 53-00-53-2R-6 REPAIR 6, SRM 51-40-05, & DWG 146A7502 REV:- AND. 146A7500 REV. MAINTENANCE ACTIONS ARE COMPLETED ON THE CARD TTG8Q006WDL9.