What was found
CRACK CENTER SCUFF PLATE AT FWD CARGO. EVALUATED CENTER SCUFF PLATE, FOUND CRACKS MEASURE AS FOLLOW; ( 1 )L=2.1145 INCHES ( 2 )L=1.1575 INCHES ( 3 )L=0.4595 INCHES ( 4 )L=0.2835 INCHES ALL THESE CRACKS MUST BE REPAIRED BY WELDS IAW SRM 53-30-15-2R-1, REPAIR 1, PARAGRAPH 4. C. REPAIRED THE SCUFF PLATE IAW SRM 53-30-15-2R-1, REPAIR 1, PARAGRAPH 4.C STEP (4) ,FIGURE 203 AND BAC 5975. PERFORMED DYE PENETRANT INSPECTION ON WELDED AREAS IAW SOPM 20-20-02 AND SRM 53-30-15-2R-1 REPAIR 1 PARAGRAPH 4.C. STEP (4). CRACK INDICATIONS NOT FOUND. APPLIED TWO LAYERS OF BMS 10-11 TYPE L PRIMER TO THE INNER SURFACE OF THE MIDDLE SCUFF PLATE IAW SRM 53-30-15-2R-1 REPAIR 1 PARAGRAPH 4.C STEPS (5)(6)(7).