What was found
CRACK WEB LOCATED BTW BS 294 - 303.9, STR16L AT FWD GALLEY AREA. MEASURED OF CRACK L:0.279 INCHES. EVALUATED CRACK ON WEB AND NO FOUND ALLOWABLE DAMAGE IN SRM, MUST BE REPLACED. REMOVED WEB, STRAP AND CLIP IAW SRM 51-40-02 AND PERFORMED VISUAL INSPECTION OF AREA AND NO FOUND DAMAGE. DRILLED NEW WEB AND APPLIED PROTECTIVE ON HOLES OF WEB IAW SRM 51-40-05 AND 51-20-01. INSTALLED WEB, STRAP AND CLIP IAW SRM 51-40-02, AND DWG 141A8180, SHEET 27, REV C.