As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK SERVICE DOOR CUT OUT STUD FRAME LOCATED BS 294 AND STR 8R AT FWD GALLEY AREA ; 2021-429864 / [24] REPLACED STUD FRAME LOCATED BS 294 AND STR 8R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02 AND DRAWING 141A8370 SHEET 1 REV C. DUE TO NOT FOUND ALLOWABLE DAMAGE ON B737-700 SRM... RII ITEM