What was found
CORROSION ON CARGO NET TIE-DOWN BRACKET AT BS 787 TO 787+4; LBL 17; WL 154. REMOVED CORROSION ON CARGO NET TIE-DOWN BRACKET. REWORKED AREA L=4' W= 1.2' D= 0.045' ORIGINAL THICKNESS .250' AFTER FURTHER EVALUATION FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2. LOCATED AND DRILLED NEW ACB TIE DOWN TRACK FROM BS 727 + 4 TO BS 867 LBL 17 IAW SRM 51-40-05 AND DWG 146A7500. REMOVED ACB TIE DOWN TRACK IAW SRM 51-40-02. INSTALLED NEW ACB TIE DOWN TRACK IAW SRM 51-40-02 AND DWG 146A7500.