What was found
CRACKED STRINGER 26R, BS 540, WL 153. REMOVED FASTENERS FROM STRINGER IAW SRM 51-40-02-0G-0. EVALUATED CRACK AND FOUND OUT OF LIMITS IAW SRM 53-00-03-1A-1, PARA 4A(2)(A)1. FABRICATED, LOCATED & DRILLED A NEW STRINGER SECTION AND SPLICE IAW SRM 53-00-03-2R-1, FIG 205. APPLIED CHEMICAL CONVERSION COATING ON REPAIR PARTS IAW SRM 53-00-03-2R-1, PARA 4.I. APPLIED PRIMER ON REPAIR PARTS IAW SRM 53-00-03-2R-1. PERFORMED VISUAL INSPECTION, NO MORE DAMAGE FOUND IAW SRM 53-00-03-2R-1, REPAIR 1 STEP 4B(1). HFEC INSPECTED CUT EDGES IAW NDTM PART 6 51-00-00 PROCEDURE 23; NO CRACKS NOTED. INSTALLED THE NEW STRINGER SECTION AND SPLICE IAW SRM 53-00-03-2R-1, REPAIR 1, SOPM 20-50-19 AND DWG 143A3230 REV A.