What was found
SUPPLEMENTAL INFORMATION: CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S..727A+10; 727B+5; 727B+8; 727C+14; 727D+2; 727D+4; 727D+5; 727D+7; 727D+10 AND 727D+15; L.B.L. 22; W.L. 154. ; / [23] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT LOCATED BTW B/S 727 TO B/S 847 LBL 22 WL 154 IAW SRM 51-40-02 AND DWG 146A7502 REV:-. AND 146A7500 REV:A; [24] VERIFIED CORRECTIVE ACTION ENTRY 23.; [25] VERIFIED CARD COMPLETE