What was found
SUPPLEMENTAL INFORMATION: CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S..727E+10; 727E+14; 727E+15; 727E+18; 727E+19; 747; 747+2; 747+5; 747+6 AND 747+10; R.B.L. 22; W.L. 154. ; / [01] REMOVED AND EVALUATED MULTIPLE AREAS OF CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT R/H FROM BS 727E+10 TO BS 747+10 RBL 22 WL 154. LARGEST AREA OF MATERIAL REMOVED MEASURES 2.4' L; 0.98' W; 0.18' D. DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMAINDER OF WORK TO BE ACCOMPLISHED ON TASK TTG8Q006S5CK.; [02] VERIFIED CORRECTIVE ACTION STEP 1; [03] REMOVED AND EVALUATED MULTIPLE AREAS OF CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT R/H FROM BS 727E+10 TO BS 747+10 RBL 22 WL 154. LARGEST AREA OF MATERIAL REMOVED MEASURES 2.4' L; 0.98' W; 0.18' D. DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMAINDER OF WORK TO BE ACCOMPLISHED ON TASK TTG8Q006S5CK; [04] VERIFIED ACTION 3