As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PANEL 561BB HAS SEVERAL PULLED FASTENER HOLES. FABRICATED REPAIR PLIES. INSTALLED REPAIR PLIES IAW SRM 51-70-04-2R-9 PARA 4.J-M. RESISTANCE CHECKED GOOD IAW AMM 51-21-71-370-801 PARA 3.D(2-4) AND 3.D(7)(A). FASTENER HOLES WERE LOCATED AND COUNTERSINKED USING TEMPLATE PRIOR TO REFINISH IAW SRM 51-70-04-2R-9.PARA 4.N.