What was found
CORROSION FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 480+14 TO BS 440+6 LBL25 WL156 ; / [01] REMOVED CORROSION AT FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW BS 440+6 TO BS 480+14; LBL 25 WL 156 PER SRM 51-10-02; MAX.MATERIAL LOSS; MEASURE L=1.4' X W= 1.' X D= 0.020' REMAINING THICKNESS IS 0.020'; ORIG.THICKNESS 0.040' BAC1496-444. PER SRM 53-30-53-0I-2 IDENTIFICATION 2 TABLE 2 ITEM[1] REWORKED AREA FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 PARAG.4.A.(2) DETAIL D FIG.103. RECEIVED LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT MAT. IAW SRM 51-40-02-0G-0 AND DWG#143A7500.