What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT STATION 747+18; RBL 21; WL 154 ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT RBL21, WL 154, BS 747E+18, MEASURES L=0.600'; W=0.500'; D=0.007'. ORIGINAL THICKNESS=0.040', MATERIAL REMOVED, 0.007', REMAINING MATERIALTHICKNESS 0.033'. THE SIDEWALL SUPPORT IS OUT OF LIMITS. I.A.W. SRM 53-00-53-1A-2; ALLOWABLE DAMAGE 2; STEP 4.2A. TOOL USED MICROMETER ID:ATS1671; DUE DATE: 01/2022.; [02] INSPECTED AND VERIFIED ACTION 1; [03] THIS DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q006Q898..