What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT RBL 21; WL 154; BS 727E+18. REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT, MEASURES L=0.750, W=0.300, D=0.008'. ORIGINAL 0.040', REMOVED=0.008', REMAINING THICKNESS 0.032'. THE SIDEWALL SUPPORT IS OUT OF LIMITS. IAW SRM 53-00-53-1A-2, ALLOWABLE DAMAGE 2, STEP 4.2A. INSPECTED AND VERIFIED ACTION 1;2. THIS DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q006Q898. .