As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500 -BS500B LBL24 WL156. ; / [24] INSTALLED FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS 396-500D LBL24 WL 156 IAW SRM 51-40-02 ;DWG 143A7500 REV:- AND DWG 143A7505 REV:D.; [25] VERIFIED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT INSTALLED AT BS 396-500D LBL 24 WL 156 PER SRM 51-40-02 ;DWG 143A7500 REV:- AND DWG 143A7505 REV:D.