As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A -BS500D RBL24 WL156. ; / [16] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS 500A-500D RBL 24 WL 156;IAW SRM 51-40-02 ;DWG 143A7500 REV:- AND DWG 143A7505 REV:D.; [17] VERIFIED INSTALLATION OF THE FLOOR TO SIDEWALL SUPPORT BS500500D RBL 24 WL156 PER SRM 51-40-02; DWG 143A7500 REV:- AND DWG 143A7505 REV:D.