What was found
TOP OF L1 DOOR CUTOUT AT BS 312 CIRCUNFERENTIAL CRACKED. CONFIRMED CRACK IAW NDTM PART 6;51-00-00 PROCEDURE 23. CRACK LENGTH 0.394. CUTOUT DAMAGED AREA IAW SRM 53-10-07-2R-1, DETAIL A. PERFORMED HFEC AT CUTOUT IAW NDTM PART 6;51-00-00 PROCEDURE 23. NO CRACKS. PERFORMED HFEC ROTO ON OPEN FASTENER HOLES IAW NDTM PART 6, 51-00-00, PROCEDURE 16. NO CRACKS. REPAIRED IAW SRM 53-10-07-2R-1, AMM 51-21-72, AND SRM 53-10-07-2R-1, REPAIR 1.