What was found
AFT CARGO DOOR CUTOUT WEB CORRODED AT WL 153, BS 787+8, RBL 20, BS 787+10; RBL 22, BS 787+11.5, RBL 24, BS 787+3, RBL 24, BS 787+14, RBL 26, AND BS 787+16, RBL 26. DAMAGE FOUND TO BE OUT LIMITS IAW SRM 53-60-15-1A-1, PAR 4G. LOCATED AND DRILLED NEW WEB IAW SRM 51-40-05-OG-0 DWG 146A8123. INSTALLED THE NEW CUTOUT WEB IAW DWG 146A8340 REV-, AND SRM 51-40-02.