What was found
CRACK FRAME ON BS500A BTW STR8R TO STR9R AT PASSENGER CABIN. MEASURE OF CRACK IS L: 0.137 INCH. EVALUATED ALLOWABLE DAMAGE LIMITS FOR CRACK IS OUT LIMITS IAW SRM 53-00-07-1A-1, FIG 102, DETAILS A, B AND E. PERFORMED HAND LAYOUT ON REPAIR AREA IAW EA 1-A53-12114. PERFORMED PERMANENT RAPAIR FRAME IAW EA E/A 1-A53-12114 REV 7.