What was found
CRACK WEB LOCATED BTW BS 400 & 420, S26L. REMOVED WEB IAW SRM 51-40-02. ALLOWABLE DAMAGE LIMITS FOR CRACK ON WEB INTERCOSTAL NOT FOUND IN SRM. DRILLED NEW HOLES ON WEB IAW SRM 51-40-05. INSTALLED NEW WEB IAW SRM 51-40-02, AND DWG 143A7505, SHEET 2, REV B.