What was found
A-061 DOT 2 CORROSION FWD PIT THRESHOLD WEB UPPER SURFACE STA 460 +10' TO STA 480 + 10' RBL 29 WL 155 ; / [01] UPDATED MEASUREMENTS IN CHART; [02] REMOVED CORROSION IAW 51-10-02 10X MAGNIFYING; [03] VERIFIED MEASUREMENTS AND CORROSION REMOVAL ITEMS 1 AND 2; [04] FOUND TO BE IN LIMITS IAW 53-30-15-1A-1 ORIGINAL THICKNESS.050 .005 MATERIAL WAS REMOVED.045 MATERIAL REMAINS AAR36649 DUE DATE12 AUG 22; [05] VERIFIED ACTION 4 IS COMPLETE; [06] VERIFIED STEPS 1-5 AND OK TO TREAT AND PRIME; [07] ALODINED IAW AMM 51-21-41-370-803<BR>PRIMED IAW AMM 51-21-72-370-801; [08] VERIFIED ACTION 7 IS COMPLETE; [09] VERIFIED ITEMS 7 AND 8; [10] AUDIT C/W