What was found
FUSELAGE SKIN STA 947.5+6' BETWEEN STR26L AND 27L HAS SPOTS OF CORROSION AROUND DRAIN HOLE. ; / [01] STRIPPING AREA NO FOUND CORROSION AS PER B-737-700 AMM 51-21-11-150-801.; [02] VERIFIED STEP 1<BR>OK TO TREAT AND PRIME; [03] APPLIED TREAT AND PRIME AT AREA STRIPPED AS PER B-737-700 SRM- 51-20-01-0G-0; [04] VERIFIED STEP # 3.; [05] OK TO TOPCOAT; [06] APPLIED TOP COATED AT FUSELAGE SKIN AT STA 947.5+6' BETWEEN STR 26L AND 27L AS REF. B737-700 AMM 51-21-73-370-803; [07] CERTIFIED STEP #6