What was found
CORROSION FOUND AFT CARGO COMPARTMENT FLOOR SUPPORT RAIL FROM STA 887 TO STA 947.5 AT RBL 8.1 HAS CORROSION AROUND FASTENER HOLES. ; / [01] REMOVED CORROSION AT AFT CARGO COMPT FLOOR RAIL FROM STA 887 TO STA 947.5 AT RBL 8.1 AS PER REF B737-700 AMM 51-10-02-0G-0; [02] VERIFIED STEP # 1.; [03] PERFORMED UT THICKNESS INSP. ON REWORKED AREAS IAW B737 NDT PART 4; 51-00-00; PROCEDURE 3. MIN. THICKNESS 0.050'<BR>TOOL: OLYMPUS 27MG B/C: 172139 DUE: 04/01/2022; [04] ORIGINAL TIKCNESS .063' ; MATERIAL LOST 0.013; MATERIAL REMAINING 0.050' . FOUND OUT OF LIMITS AS PER REF B737-700 SRM 53-00-53-1A-2; [05] VERIFIED STEP # 4.; [06] REMOVED AFT CARGO FLOOR SUPPORT RAIL FROM STA 887 TO STA947.5 AS PER REF B737-700 SRM 51-40-05-0G-0; [07] FABRICATED NEW FLOOR SUPPORT RAIL FROM STA 887 TO STA 94.5 AT RBL 8.1 AS PER REF B737-700 DRAWING 147A7501 AND SRM 51-40-05-0G-0; [08] VERIFIED STEPS 6 AND 7. OK TO TREAT AND PRIME.; [09] APPLIED TREAT AND PRIME AT NEW FLOOR SUPPORT RAIL AS PER REF B 737-700 AMM 51-21-72-370-804; [10] VERIFIED STEP #9.; [11] OK TO INSTALL FLOOR SUPPORT RAIL.; [12] INSTALLED FLOOR SUPPORT RAIL AT AFT CARGO FROM STA 887 TO STA 947.5 RBL 8.1 AS PER REF B737-700 SRM 51-40-02-0G-0 AND DRAWING 147A7501; [13] VERIFIED STEP # 12.; [14] REMOVED CORROSION AT AFT CARGO COMPT FLOOR RAIL FROM STA 887 TO STA 947.5 AT RBL 8.1. FOUND OUT LIMITS; REMOVED AND REPLACED RAIL AS PER REF B737-700 SRM 51-40-02-0G-0 AND DRAWING 147A7501 .; [15] VERIFIED STEP 14.