As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO BAY DOOR CUTOUT FWD SHIELD IS CORRODED AT WL 153; BS 767+1; RBL 20; 767+2.5; RBL 22; 767+4; RBL 20; 767+7; RBL 22; 767+8; RBL 20; 767+11; RBL 22; 767+15; RBL 22. DAMANGE FOUND ON FWD SHIELD, FOUND TO BE OUT OF LIMIT IAW SRM 51-10-02-0G-0 PAR. 9C. LOCATED AND DRILLED NEW SHILD IAW SRM 51-40-05-OG-0 & DWG 146A8127. INSTALLED NEW SHIELD IAW SRM 51-40-02-0G-0 &DWG 146A8127.