What was found
# 22 BULLNOSE EMERGENCY LIGHT LENS COVER MISSING ; / [01] OK TO CONTINUE PER MEL 33-15-02. SP 1. LOG PAGE # 1901907; [02] INSPECTED AND FOUND LENS MISSING AND RETAINER/HOUSING DIS-BONDED FROM BULLNOSE PANEL. NO PARTS IN STOCK AT THIS TIME. REMOVED AND REPLACED EMERGENCY LIGHT LENS HOUSING AND LENS IAW AMM 33-51-01. OPS CHECK GOOD.