What was found
CRACKED STRINGER AT AREA AFT OF FCB BS540 S-23R WL164. MARKED ; / [21] INSTALLED REPLACEMENT STRINGER SECTION BS 500D+12 TO 540 AND HAT SECTION REPAIR BS 500D+4 TO 500D+16 STR 23R/H WL 164 IAW SRM 53-00-03-2R-1 AND SRM 51-40-02 AND EA NO: 21-153-02931 REV A; [22] REPAIR COMPLETE; [23] VERIFIED INSTALLED REPLACEMENT STRINGER SECTION BS 500D+12 TO 540 AND HAT SECTION REPAIR BS 500D+4 TO 500D+16 STR 23R/,NG,NRC,2021-10-25 16:05:41,22Y,Y,MX,0,0,,CRACKED STRINGER AT AREA AFT OF FCB BS540 S-23R WL164. MARKED ;"